93 research outputs found

    A risk-based approach to identifying oligometastatic disease on imaging.

    Get PDF
    Recognition of <3 metastases in <2 organs, particularly in cancers with a known predisposition to oligometastatic disease (OMD) (colorectal, prostate, renal, sarcoma and lung), offers the opportunity to focally treat the lesions identified and confers a survival advantage. The reliability with which OMD is identified depends on the sensitivity of the imaging technique used for detection and may be predicted from phenotypic and genetic factors of the primary tumour, which determine metastatic risk. Whole-body or organ-specific imaging to identify oligometastases requires optimization to achieve maximal sensitivity. Metastatic lesions at multiple locations may require a variety of imaging modalities for best visualisation because the optimal image contrast is determined by tumour biology. Newer imaging techniques used for this purpose require validation. Additionally, rationalisation of imaging strategies is needed, particularly with regard to timing of imaging and follow-up studies. This article reviews the current evidence for the use of imaging for recognising OMD and proposes a risk-based roadmap for identifying patients with true OMD, or at risk of metastatic disease likely to be OM

    Is perfect the enemy of good? Weighing the evidence for biparametric MRI in prostate cancer

    Get PDF
    The role of multiparametric MRI in diagnosis, staging and treatment planning for prostate cancer is well established. However there remain several challenges to widespread adoption. One such challenge is the duration and cost the examination. Abbreviated exams omitting contrast enhanced sequences may help address this challenge. In this review, we will discuss the rationale for biparametric MRI (bpMRI) for detection and characterization of clinically significant prostate cancer prior to biopsy and synthesize the published literature. We will weigh up the advantages and disadvantages to this approach and lay out a conceptual cost/benefit analysis regarding adoption of bpMRI

    Artificial intelligence in cancer imaging: Clinical challenges and applications

    Get PDF
    Judgement, as one of the core tenets of medicine, relies upon the integration of multilayered data with nuanced decision making. Cancer offers a unique context for medical decisions given not only its variegated forms with evolution of disease but also the need to take into account the individual condition of patients, their ability to receive treatment, and their responses to treatment. Challenges remain in the accurate detection, characterization, and monitoring of cancers despite improved technologies. Radiographic assessment of disease most commonly relies upon visual evaluations, the interpretations of which may be augmented by advanced computational analyses. In particular, artificial intelligence (AI) promises to make great strides in the qualitative interpretation of cancer imaging by expert clinicians, including volumetric delineation of tumors over time, extrapolation of the tumor genotype and biological course from its radiographic phenotype, prediction of clinical outcome, and assessment of the impact of disease and treatment on adjacent organs. AI may automate processes in the initial interpretation of images and shift the clinical workflow of radiographic detection, management decisions on whether or not to administer an intervention, and subsequent observation to a yet to be envisioned paradigm. Here, the authors review the current state of AI as applied to medical imaging of cancer and describe advances in 4 tumor types (lung, brain, breast, and prostate) to illustrate how common clinical problems are being addressed. Although most studies evaluating AI applications in oncology to date have not been vigorously validated for reproducibility and generalizability, the results do highlight increasingly concerted efforts in pushing AI technology to clinical use and to impact future directions in cancer care

    Treatment of esophageal tumors using high intensity intraluminal ultrasound: first clinical results

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Esophageal tumors generally bear a poor prognosis. Radical surgery is generally the only curative method available but is not feasible in the majority of patients; palliative therapy with stent placement is generally performed. It has been demonstrated that High Intensity Ultrasound can induce rapid, complete and well-defined coagulation necrosis. Thus, for the treatment of esophageal tumors, we have designed an ultrasound applicator that uses an intraluminal approach to fill up this therapeutic gap.</p> <p>Methods</p> <p>Thermal ablation is performed with water-cooled ultrasound transducers operating at a frequency of 10 MHz. Single lesions extend from the transducer surface up to 10 mm in depth when applying an intensity of 14 W/cm<sup>2 </sup>for 10s. A lumen inside the therapy applicator provides path for an endoscopic ultrasound imaging probe operating at a frequency of 12 MHz. The mechanical rotation of the applicator around its axis enables treatment of sectorial or cylindrical volumes. This method is thus particularly suitable for esophageal tumors that may develop only on a portion of the esophageal circumference. Previous experiments were conducted from bench to <it>in vivo </it>studies on pig esophagi.</p> <p>Results</p> <p>Here we report clinical results obtained on four patients included in a pilot study. The treatment of esophageal tumors was performed under fluoroscopic guidance and ultrasound imaging. Objective tumor response was obtained in all cases and a complete necrosis of a tumor was obtained in one case. All patients recovered uneventfully and dysphagia improved significantly within 15 days, allowing for resuming a solid diet in three cases.</p> <p>Conclusion</p> <p>This clinical work demonstrated the efficacy of intraluminal high intensity ultrasound therapy for local tumor destruction in the esophagus.</p

    Ultrasound-Guided Radiofrequency Thermal Ablation of Uterine Fibroids: Medium-Term Follow-Up

    Get PDF
    Previous studies have shown that radiofrequency thermal ablation (RFA) of uterine fibroids through a percutaneous ultrasound (US)-guided procedure is an effective and safe minimally invasive treatment, with encouraging short-term results. The aim of this study was to assess the results in terms of volume reduction and clinical symptoms improvement in the midterm follow-up of fibroids with a diameter of up to 8 cm. Eleven premenopausal females affected by symptomatic fibroids underwent percutaneous US-guided RFA. Symptom severity and reduction in volume were evaluated at 1, 3, 6, 9, and 12 months. The mean symptom score (SSS) before the procedure was 50.30 (range 31.8–67.30), and the average quality of life (QOL) score value was 62 (range 37.20–86.00). The mean basal diameter was 5.5 cm (range 4.4–8) and the mean volume was 101.5 cm3 (range 44.58–278 cm3). The mean follow-up was 9 months (range 3–12 months). The mean SSS value at the end of the follow-up was 13.38 (range 0–67.1) and the QOL 90.4 (range 43.8–100). At follow-up the mean diameter was 3.0 cm (range 1.20–4.5 cm), and the mean volume was 18 cm3 (range 0.90–47.6 cm3). In 10 of 11 patients we obtained total or partial regression of symptoms. In one case the clinical manifestations persisted and it was thus considered unsuccessful. In conclusion, US-guided percutaneous RFA is a safe and effective treatment even for fibroids up to 8 cm

    Investigation of Cellular and Molecular Responses to Pulsed Focused Ultrasound in a Mouse Model

    Get PDF
    Continuous focused ultrasound (cFUS) has been widely used for thermal ablation of tissues, relying on continuous exposures to generate temperatures necessary to induce coagulative necrosis. Pulsed FUS (pFUS) employs non-continuous exposures that lower the rate of energy deposition and allow cooling to occur between pulses, thereby minimizing thermal effects and emphasizing effects created by non-thermal mechanisms of FUS (i.e., acoustic radiation forces and acoustic cavitation). pFUS has shown promise for a variety of applications including drug and nanoparticle delivery; however, little is understood about the effects these exposures have on tissue, especially with regard to cellular pro-homing factors (growth factors, cytokines, and cell adhesion molecules). We examined changes in murine hamstring muscle following pFUS or cFUS and demonstrate that pFUS, unlike cFUS, has little effect on the histological integrity of muscle and does not induce cell death. Infiltration of macrophages was observed 3 and 8 days following pFUS or cFUS exposures. pFUS increased expression of several cytokines (e.g., IL-1α, IL-1β, TNFα, INFγ, MIP-1α, MCP-1, and GMCSF) creating a local cytokine gradient on days 0 and 1 post-pFUS that returns to baseline levels by day 3 post-pFUS. pFUS exposures induced upregulation of other signaling molecules (e.g., VEGF, FGF, PlGF, HGF, and SDF-1α) and cell adhesion molecules (e.g., ICAM-1 and VCAM-1) on muscle vasculature. The observed molecular changes in muscle following pFUS may be utilized to target cellular therapies by increasing homing to areas of pathology